logo
FAMOUS Steel Engineering Company
products
products
Home > products > Industrial Steel Buildings > Steel Shed Warehouse Industrial Steel Buildings Hot Dip Galvanized Web Truss Rafter UB UC Column Frame

Steel Shed Warehouse Industrial Steel Buildings Hot Dip Galvanized Web Truss Rafter UB UC Column Frame

Product Details

Place of Origin: Zhejiang, China

Brand Name: FAMOUS

Certification: ISO 9001

Model Number: Steel Shed Warehouse Frame

Payment & Shipping Terms

Minimum Order Quantity: 1000

Price: USD 12-20/SQM

Packaging Details: Steel strapped bundles with edge protection, marked with profile, thickness and length, loaded in 20ft or 40ft container

Delivery Time: 15 to 25 days after drawing confirmation

Payment Terms: L/C,D/A,D/P,T/T

Supply Ability: 2,000 – 5,000 MT/month

Get Best Price
Highlight:

warehouse steel frame

,

hot dip galvanized shed

,

web truss rafter frame

Frame Type:
Portal Frame With UC Columns And Web Truss Rafters
Columns:
Universal Column UC Or Universal Beam UB, Base Plates And Knee Plates Shop Finished
Rafters:
Web Truss Rafters With UB Or UC Chords And Welded Web Members
Clear Height:
Set By Racking Height And Truss Depth
Column Grid:
Set To Racking Module And Aisle Layout
Surface Treatment:
Hot Dip Galvanized After Fabrication
Coating Class:
Matched To Internal Environment And Service Life
Secondary Framing:
Galvanized C Or Z Purlins And Girts With Bracing
Openings:
Dock Doors Roller Doors Windows And Louvers Framed To Schedule
Services Zone:
Open Zone Between Truss Chords For Sprinkler Lighting And Ventilation
Design Basis:
Wind Region Roof Load Deflection Seismic Crane And Mezzanine As Applicable
Documents:
GA And Erection Drawings Anchor Plan Coating Report And Packing List
Frame Type:
Portal Frame With UC Columns And Web Truss Rafters
Columns:
Universal Column UC Or Universal Beam UB, Base Plates And Knee Plates Shop Finished
Rafters:
Web Truss Rafters With UB Or UC Chords And Welded Web Members
Clear Height:
Set By Racking Height And Truss Depth
Column Grid:
Set To Racking Module And Aisle Layout
Surface Treatment:
Hot Dip Galvanized After Fabrication
Coating Class:
Matched To Internal Environment And Service Life
Secondary Framing:
Galvanized C Or Z Purlins And Girts With Bracing
Openings:
Dock Doors Roller Doors Windows And Louvers Framed To Schedule
Services Zone:
Open Zone Between Truss Chords For Sprinkler Lighting And Ventilation
Design Basis:
Wind Region Roof Load Deflection Seismic Crane And Mezzanine As Applicable
Documents:
GA And Erection Drawings Anchor Plan Coating Report And Packing List
Steel Shed Warehouse Industrial Steel Buildings Hot Dip Galvanized Web Truss Rafter UB UC Column Frame
Industrial Steel Buildings

Steel Shed and Warehouse Frames Built Around What Happens Inside

A shed keeps weather out. A warehouse also has to serve racking, forklifts, dock traffic, sprinklers and often a mezzanine. The frame is the same product family, but the decisions change with the operation, and those decisions are cheapest to make before the first member is drawn.

Steel Shed Warehouse Industrial Steel Buildings Hot Dip Galvanized Web Truss Rafter UB UC Column Frame

01 The Frame Follows The Operation

Most steel shed and warehouse enquiries arrive as a size: so many metres long, so many wide, so high. That is enough to quote a structure, but not enough to design a working building. The operational requirements are what set the clear height, the column grid, the openings and the bracing layout.

This frame package is detailed the same way in both cases: hot dip galvanized UB and UC columns, web truss rafters across the span, galvanized secondary steel, everything fabricated to the drawing. What changes is which member is asked to do what.

Steel Shed Warehouse Industrial Steel Buildings Hot Dip Galvanized Web Truss Rafter UB UC Column Frame

02 From Requirement To Structural Decision

What Happens Inside What It Changes On The Frame
High bay racking Clear height under the haunch and the truss depth both matter. A truss rafter keeps the roof structure light and still leaves the service zone above the racking, while the column grid is set to the racking module rather than a default bay.
Forklift and pedestrian traffic Column positions become traffic islands. Galvanized columns survive impact without the paint damage that starts a rust patch, and base details are kept out of the wheel path where possible.
Loading docks and truck access Dock openings concentrate load and remove wall bracing at that line, so the opening frame, lintel and the remaining bracing have to be designed together. Canopy and dock framing are part of the package.
Sprinkler, lighting and ventilation The open zone between truss chords carries services instead of pushing them below the structure, which protects the clear height you paid for.
Mezzanine or internal floor The mezzanine load lands on the column line, so the column section and the connection change from a simple frame member into a loaded one. It is cheaper to say this at enquiry stage than to add it later.
Overhead crane or hoist A runway beam and its bracket change the column design, the eaves detail and often the bracing. The crane duty class and hook height are design inputs, not accessories.
Cold store or wash down Moisture on the inside face is the corrosion driver, so the coating class, the insulation and the vapour path are settled with the frame, not left to the cladding supplier.
Future expansion Bays are detailed as a repeatable module, so a later extension reuses the section set instead of starting a new design.

03 The Frame Under All Of It

Columns. Rolled universal column UC sections in the vertical position, because the UC profile suits compression plus the bending from wind and brackets, and it is standard, traceable mill material. Where a wider flange suits the design, a universal beam UB is used as the column. Where the depth is outside the rolled range, the member is welded up from plate to the exact size. Base plates, stiffeners and knee plates are finished in the shop, so site work is bolting.

Rafters. Web truss rafters with UB or UC chords and welded vertical and diagonal web members. Depth is built from geometry rather than steel mass, so a long span is carried on a lighter member, and the depth becomes the service zone for the building. Truss depth, chord size and web pattern follow the span, the roof load and the available headroom.

Jig welded, checkedChords set in a jig, tacked, checked for depth and square, welded to a planned sequence and trial assembled before marking.
Panel points alignedPurlin lines, brace points and splices land on panel points, so loads enter where the geometry can carry them.
Deflection governsCladding and drainage fall usually control the size before stress does, so the rafter is designed against deflection.
Spliced for transportLong trusses are spliced at locations that suit containers, the galvanizing bath and the site crane, then bolted into one line.

04 Galvanized, Because A Warehouse Is Hard On Steel

Galvanizing is applied after the member is fully fabricated, so the zinc reaches the cut ends, the inside of every bolt hole, the back of every cleat and the weld toes. In a working warehouse those are exactly the places that get damaged, washed or left wet.

  • No post-coating work. Cutting, drilling and welding are finished before dipping, because a hole made afterwards leaves bare steel inside the bore.
  • Vented and drained. Closed members get vent and drain holes in the detail, so zinc enters and drains properly.
  • Coating class matched to use. A dry storage warehouse and a wash down area should not carry the same coating specification.
  • Reported per batch. Coating mass and thickness measured and issued with mill certificates per heat number.
  • Duplex available. Where a colour finish is specified, primer and top coat are applied over the zinc.

Steel Shed Warehouse Industrial Steel Buildings Hot Dip Galvanized Web Truss Rafter UB UC Column Frame

05 Openings, Docks And Wall Lines

  • Roller doors, access doors, windows and louvers framed with lintels and jambs sized for the opening
  • Dock openings coordinated with the bracing layout, so removing a brace at the opening does not leave the wall plane unstable
  • Canopy and awning framing included where trucks load under cover
  • Gutter, downpipe and valley outlets positioned before the slab is poured
  • All fixing holes for doors, flashings and brackets drilled before coating

06 What To Send Us

Size and shapeLength, width, span layout, bay spacing, eave height and roof pitch.
OperationWhat is stored or handled, racking height, forklift types, dock traffic, any crane or mezzanine.
Site conditionsWind region and terrain category, coastal or inland, snow if applicable, and the ground conditions if known.
Envelope intentSingle skin or insulated panel, roof colour, skylights and ventilation expected.
Service lifeExpected life and whether the building will be washed down or hold moisture.
DrawingsArchitectural or structural drawings if they exist, and any planning conditions the frame has to meet.

With those, the frame can be sized once instead of guessed and revisited. If something is not yet decided, say so: it is still useful to know which items are open, because those are the ones that change section sizes later.

07 What You Can Specify

Geometry

  • Span, length, bay spacing and number of frames
  • Eave height, ridge height and roof pitch, gable or monoslope
  • Clear span or multi span, and where internal columns may sit
  • Dock, canopy and awning framing

Frame

  • Column section, orientation and base fixity
  • Rafter type, truss depth, chord section and web member pattern
  • Crane runway, mezzanine and canopy brackets where required
  • Splice positions and lifting points

Envelope And Openings

  • Purlin and girt spacing to suit cladding and insulation
  • Single skin or insulated sandwich panel
  • Roller doors, access doors, windows, louvers and skylights
  • Gutter, valley and downpipe arrangement

Design Basis

  • Wind region, terrain category and cyclonic exposure where applicable
  • Roof live load, collateral load and hanging services load
  • Deflection limits for cladding and drainage
  • Seismic parameters and importance level, plus service life for coating class
Send the operation, not just the size. A twenty metre wide shed for hay and the same shed for high bay racking are different structural problems, and the frame that suits one will not suit the other.

08 Package, Documents And Process

  • Galvanized UC columns with base plates, stiffeners and knee plates
  • Galvanized web truss rafters with bolted site splices
  • Galvanized purlins, girts, bracing, sag rods and fly braces
  • Framed openings, dock, gutter and canopy brackets
  • Bolts, anchor bolts and fixing accessories specified for galvanized steel
  • 3D model, general arrangement drawings, erection drawings, anchor setting plan, mill certificates, coating report and packing list
  • You send the operation, size, site conditions and any drawings.
  • We set the frame route, the section sizes and the coating class, then quote.
  • General arrangement drawings and member details are issued for approval.
  • Members are fabricated, trial assembled where required and piece marked.
  • The frame is hot dip galvanized, inspected and issued with a coating report.
  • Members are packed by piece mark and shipped in erection sequence.
Tell us what the building has to do Send the size and the operation, and we will detail the frame around both.