logo
FAMOUS Steel Engineering Company
products
products
Home > products > Industrial Steel Buildings > Galvanized Industrial Steel Buildings UB UC Columns Web Truss Rafters Large Span Steel Shed Warehouse

Galvanized Industrial Steel Buildings UB UC Columns Web Truss Rafters Large Span Steel Shed Warehouse

Product Details

Place of Origin: Zhejiang, China

Brand Name: FAMOUS

Certification: ISO 9001

Model Number: Large Span Galvanized Shed Frame

Payment & Shipping Terms

Minimum Order Quantity: 1000

Price: USD 12-20/SQM

Packaging Details: Steel strapped bundles with edge protection, marked with profile, thickness and length, loaded in 20ft or 40ft container

Delivery Time: 15 to 25 days after drawing confirmation

Payment Terms: L/C,D/A,D/P,T/T

Supply Ability: 2,000 – 5,000 MT/month

Get Best Price
Highlight:

large span steel shed

,

large span warehouse frame

,

galvanized UB UC column frame

Span:
Clear Span Or Multi Span Set By Building Layout
Bay Spacing:
Optimised Against Frame And Purlin Weight
Column Section:
Universal Column UC Or UB With Orientation Set To Bending Direction
Rafter Type:
Web Truss Rafter Or Solid Rafter Compared On Tonnage And Deflection
Truss Depth:
Sized For Span Roof Load And Deflection Limit
Splices:
Located For Transport Bath And Crane Limits
Surface Treatment:
Hot Dip Galvanized After Fabrication
Galvanizing Standard:
As Named In Project Specification With Coating Class Matched To Site
Secondary Framing:
Galvanized C Or Z Purlins And Girts With Bracing And Sag Rods
Cladding:
Single Skin Sheeting Or Insulated Sandwich Panel As Specified
Openings:
Framed Openings To Door Window And Louver Schedule
Design Basis:
Wind Region Roof Load Deflection Seismic And Crane Load As Applicable
Documents:
3D Model GA And Erection Drawings Anchor Plan And Coating Report
Erection:
Bolted Site Assembly With Bay And Frame Referenced Piece Marks
Span:
Clear Span Or Multi Span Set By Building Layout
Bay Spacing:
Optimised Against Frame And Purlin Weight
Column Section:
Universal Column UC Or UB With Orientation Set To Bending Direction
Rafter Type:
Web Truss Rafter Or Solid Rafter Compared On Tonnage And Deflection
Truss Depth:
Sized For Span Roof Load And Deflection Limit
Splices:
Located For Transport Bath And Crane Limits
Surface Treatment:
Hot Dip Galvanized After Fabrication
Galvanizing Standard:
As Named In Project Specification With Coating Class Matched To Site
Secondary Framing:
Galvanized C Or Z Purlins And Girts With Bracing And Sag Rods
Cladding:
Single Skin Sheeting Or Insulated Sandwich Panel As Specified
Openings:
Framed Openings To Door Window And Louver Schedule
Design Basis:
Wind Region Roof Load Deflection Seismic And Crane Load As Applicable
Documents:
3D Model GA And Erection Drawings Anchor Plan And Coating Report
Erection:
Bolted Site Assembly With Bay And Frame Referenced Piece Marks
Galvanized Industrial Steel Buildings UB UC Columns Web Truss Rafters Large Span Steel Shed Warehouse
Industrial Steel Buildings

Galvanized Steel Sheds and Warehouses at Large Span

At large span, steel weight is the cost. Every metre of span adds bending to the rafter and uplift to the base, and the frame has to be detailed so the span is carried with the least steel that still meets deflection, wind and cladding requirements.

GalvanizedLarge SpanUB UC ColumnsWeb Truss RaftersSteel ShedWarehouse

01 What Drives Steel Weight At Large Span

Two sheds with the same floor area can differ substantially in steel tonnage. The difference is rarely the steel price. It is the decisions taken before the first member is drawn.

Span WidthThe single biggest driver. Bending rises with span, so the rafter depth and the column section follow it.
Bay SpacingWider bays mean fewer frames but heavier members and heavier purlins. There is a point where the two balance, and it is worth finding.
Eave HeightA taller column carries more bending from wind and from any crane bracket, so height is not free.
Wind RegionUplift governs column and base design in exposed or cyclonic sites, which changes the frame far more than the roof load does.
Roof And Hanging LoadsCollateral load, solar, sprinkler, ventilation and any hanging services all add to what the rafter must carry.
Crane And MezzanineA runway beam or a floor inside the shed changes the column from a simple compression member into a loaded frame member.

02 Five Levers That Reduce Tonnage

LeverWhat It DoesThe Trade You Accept
Truss rafter instead of a deep solid rafterBuilds depth from two chords and a web rather than from one heavy rolled section, so the mid span mass dropsMore welding hours and a deeper roof structure, which has to fit the available headroom
Bay spacing optimisationFinds the spacing where frame weight and purlin weight balance, instead of copying a default modulePurlins and cladding spans change with it, so the whole envelope has to be checked together
Column section and orientationChoosing UB or UC and setting the web plane against the bending direction uses the section where it is strongestConnection details change, and the knee plate has to be detailed for the orientation chosen
Mixed frame routesRolled members in repeat bays, welded built up members only where the design actually needs themTwo fabrication routes in one project, which has to be reflected in piece marks and packing
Splice locationPlacing splices where the moment is low lets a long rafter ship as light pieces instead of one heavy memberMore site bolts and a splice detail that must be designed, not improvised

Table 1: the levers we work through at enquiry stage. Each one moves weight between the frame, the secondary steel and the erection cost, so they are optimised together.

03 UB And UC Sections At Span

Universal sections are efficient because the material sits where the bending stress is. The design question is which one goes where.

  • Universal column UC sections suit the vertical member, where the load is compression plus bending from wind and any crane bracket
  • Universal beam UB sections suit the spanning member, where the load is bending and deflection governs the size
  • Orientation matters: the strong axis is placed against the dominant bending direction, and the knee connection is detailed to suit it
  • Where the required depth is outside the rolled range, a welded built up H section takes over without changing the connection concept
  • Section choice is made against deflection, not only stress, because a roof that sags will crack cladding long before the steel is over stressed

04 Web Truss Rafters At Large Span

Beyond a certain span, a solid rafter becomes deep and heavy fast. The truss rafter breaks that curve by putting the chords far apart and letting the web carry the shear.

Depth Is The VariableIncrease truss depth and the chords carry less force for the same span, so tonnage drops without changing the steel grade.
Chords From Standard SectionsUB or UC chords keep the member on standard, traceable material rather than a special profile.
Panel Points Set The DetailPurlin lines, brace points and splices land on panel points, so loads enter the truss where the geometry can take them.
Service Zone IncludedThe depth you are paying for also becomes the zone for lighting, sprinkler and cable trays.

05 Long Members And Galvanizing

A large span frame contains long members, and long members meet practical limits that affect the design early: what fits in a container, what the galvanizing bath can accept, and what the site crane can lift safely.

  • Splices located for transport and bath limits, then detailed as proper bolted joints
  • Galvanizing after all fabrication, so cut ends, hole bores and weld toes are coated
  • Vent and drain holes detailed before dipping, particularly on any closed member
  • Lifting points and handling plan agreed so the coating arrives intact and the truss is not racked during erection
  • Packing with spacers and bundles in erection order, because a damaged coating on a long member is expensive to repair on site

06 Erecting A Large Span Frame

Large span frames fail on site for reasons that have nothing to do with the steel: the wrong member in the wrong bay, temporary bracing removed too early, or a truss picked up at a point it was not designed for.

  • Piece marks that state the bay and the frame number, matched to the packing list
  • Erection sequence and temporary bracing shown on the drawing, not left to the site team
  • Lifting points marked on the truss and matched to the crane plan
  • Anchor bolt setting plan issued early, so the foundation is poured to the frame and not the other way round
  • Site connections bolted with shop drilled plates, so no site drilling is needed and no coating is broken

07 What The Building Gives You

Clear Working FloorSpan carried by the roof means the floor stays free for racking, machinery and vehicle movement.
Usable HeightTruss depth is planned against eave height so the internal clear height suits what will be stored or handled.
Galvanized FrameExposed steel stays protected at cut edges, holes and impact points without a repainting programme.
Extension ReadyBays are detailed as a repeatable module, so a later extension repeats the section set instead of starting again.

08 What You Can Specify

Geometry

  • Span, building length, bay spacing and number of frames
  • Eave height, ridge height and roof pitch
  • Clear span or multi span, or a mix of both
  • Canopy, dock and awning framing

Members

  • UC column section, orientation and base fixity
  • Rafter type, truss depth, chord section and web member pattern
  • Splice positions and lifting points
  • Purlin and girt layout in galvanized C or Z
  • Crane runway, mezzanine and canopy framing where required

Protection

  • Galvanizing standard and coating class for your site environment
  • Plain galvanized or duplex with primer and top coat
  • Coating report and inspection requirements
  • Handling and packing protection for long members

Design Basis

  • Wind region, terrain category and cyclonic exposure where applicable
  • Roof live load, collateral load and hanging services load
  • Deflection limits for the cladding and drainage
  • Seismic parameters and importance level
  • Crane capacity, hook height and duty class
Send the span, bay spacing you have in mind, eave height, wind region and what will happen inside the building. We will check the tonnage against a truss rafter and against a solid rafter, and quote the lighter option that still meets deflection.

09 Package And Documents

  • Galvanized UC columns with base plates, stiffeners and knee plates
  • Galvanized web truss rafters with bolted site splices and lifting points
  • Galvanized purlins, girts, bracing, sag rods and fly braces
  • Framed openings, gutter and canopy brackets
  • Structural bolts, anchor bolts and fixing accessories
  • 3D model, general arrangement drawings, erection drawings, anchor setting plan and packing list
  • Mill test certificates per heat number and coating report per batch

10 From Span To Delivered Frame

  • You send the span, length, bay spacing, eave height, wind region and intended use.
  • We compare a truss rafter and a solid rafter on tonnage and deflection, then recommend one and quote it.
  • General arrangement drawings, member details and the anchor setting plan are issued for approval.
  • Members are cut, welded, drilled, trial assembled and piece marked by bay and frame.
  • The frame is hot dip galvanized, inspected and issued with a coating report.
  • Members are packed with coating protection and loaded in erection sequence.
Send your span and bay spacing for a tonnage check We will tell you which frame route carries the span on the least steel before you commit to a design.