Product Details
Place of Origin: Zhejiang, China
Brand Name: FAMOUS
Certification: ISO 9001
Model Number: Hot Dip Galvanized Shed Frame
Payment & Shipping Terms
Minimum Order Quantity: 1000
Price: USD 12-20/SQM
Packaging Details: Steel strapped bundles with edge protection, marked with profile, thickness and length, loaded in 20ft or 40ft container
Delivery Time: 15 to 25 days after drawing confirmation
Payment Terms: L/C,D/A,D/P,T/T
Supply Ability: 2,000 – 5,000 MT/month
Coating System: |
Hot Dip Galvanized After Fabrication With Optional Duplex Top Coat |
Galvanizing Standard: |
As Named In Project Specification |
Coating Class: |
Selected Against Site Environment And Service Life |
Vent And Drain: |
Positions Detailed Before Fabrication For Closed Members |
Thread Protection: |
Protected Or Re Tapped After Dipping |
Frame Members: |
UB UC Columns Beams And Web Truss Rafters |
Rafter Type: |
Web Truss Rafter With UB Or UC Chords And Welded Web Members |
Secondary Framing: |
Galvanized C Or Z Purlins Girts And Bracing |
Cladding: |
Single Skin Sheeting Or Insulated Sandwich Panel As Specified |
Openings: |
Framed Openings To Door Window And Louver Schedule |
Design Basis: |
Wind Region Roof Load Seismic And Service Life As Applicable |
Documents: |
GA And Erection Drawings Anchor Plan Mill Certificates And Coating Report |
Packing: |
Spacers Between Members To Protect Coating In Transit |
Erection: |
Bolted Site Assembly With Piece Marked Members |
Coating System: |
Hot Dip Galvanized After Fabrication With Optional Duplex Top Coat |
Galvanizing Standard: |
As Named In Project Specification |
Coating Class: |
Selected Against Site Environment And Service Life |
Vent And Drain: |
Positions Detailed Before Fabrication For Closed Members |
Thread Protection: |
Protected Or Re Tapped After Dipping |
Frame Members: |
UB UC Columns Beams And Web Truss Rafters |
Rafter Type: |
Web Truss Rafter With UB Or UC Chords And Welded Web Members |
Secondary Framing: |
Galvanized C Or Z Purlins Girts And Bracing |
Cladding: |
Single Skin Sheeting Or Insulated Sandwich Panel As Specified |
Openings: |
Framed Openings To Door Window And Louver Schedule |
Design Basis: |
Wind Region Roof Load Seismic And Service Life As Applicable |
Documents: |
GA And Erection Drawings Anchor Plan Mill Certificates And Coating Report |
Packing: |
Spacers Between Members To Protect Coating In Transit |
Erection: |
Bolted Site Assembly With Piece Marked Members |
Galvanizing is not a coat of paint applied at the end. It is a metallurgical bond formed by dipping a finished steel member into molten zinc, and it only works properly if the fabrication sequence and the member detail are right before the steel goes into the bath.
Paint protects steel by sealing it. Once the film is broken by a scratch, a cut edge, a bolt hole or a site impact, moisture reaches the steel and rust starts under the coating, where it cannot be seen. Galvanizing works two ways: the zinc seals the surface, and where that surface is damaged the zinc beside it corrodes first and protects the steel.
That second mechanism is the reason galvanizing suits an industrial building. Frames get hit by forklifts, purlins get drilled on site, and cladding fixings break the surface. A galvanized member survives those events; a painted one starts a rust patch at each one.
One rule governs everything else: all cutting, drilling, welding and forming must be finished before the member is dipped. A hole drilled after galvanizing exposes bare steel inside the bore, and that is exactly where corrosion begins in service.
Galvanizing rewards good detailing and punishes shortcuts. These are the details we build into the drawing before fabrication starts, because they cannot be fixed afterwards.
| Aspect | Hot dip galvanized | Paint system | Duplex, zinc plus paint |
|---|---|---|---|
| How it protects | Barrier plus sacrificial protection at damage points | Barrier only, so damage exposes steel | Both, with the paint slowing zinc consumption |
| Cut edges and holes | Coated because the member is dipped after fabrication | Coated only if the painter reaches them | Coated, then over coated |
| Site damage | Localised zinc sacrifice, no rust creep under a film | Rust creeps under a broken film and lifts it | Damage is limited by the zinc underneath |
| Maintenance | No routine repainting of the frame | Inspection and recoating cycle, with access equipment | Longer cycle than paint alone, colour retained |
| Appearance | Metallic grey zinc finish, matures with exposure | Any colour, but finish depends on site conditions | Any colour with a zinc base |
| When to choose | Industrial sheds, warehouses, coastal and humid sites, exposed frames | Indoor architectural steel where colour is the driver | Projects needing colour and maximum durability |
Table 1: protection systems compared on how they behave in service, not on price per square metre at the factory gate.
Galvanizing is a specification item, not a default. The coating class is chosen against the environment the building sits in: a rural shed, a coastal warehouse and a fertilizer store should not carry the same specification, even if the frame drawing looks identical.
The coating protects whatever the frame is. In this package the frame is universal column UC verticals, universal beam UB spanning members and web truss rafters with UB or UC chords, detailed to your drawing and galvanized as finished members.