logo
FAMOUS Steel Engineering Company
products
products
Home > products > Industrial Steel Buildings > Universal Column UC Universal Beam UB Frame Industrial Steel Buildings Web Truss Rafter Galvanized Shed

Universal Column UC Universal Beam UB Frame Industrial Steel Buildings Web Truss Rafter Galvanized Shed

Product Details

Place of Origin: Zhejiang, China

Brand Name: FAMOUS

Certification: ISO 9001

Model Number: UC Column UB Frame Web Truss Shed

Payment & Shipping Terms

Minimum Order Quantity: 1000

Price: USD 12-20/SQM

Packaging Details: Steel strapped bundles with edge protection, marked with profile, thickness and length, loaded in 20ft or 40ft container

Delivery Time: 15 to 25 days after drawing confirmation

Payment Terms: L/C,D/A,D/P,T/T

Supply Ability: 2,000 – 5,000 MT/month

Get Best Price
Highlight:

UC column UB steel frame

,

web truss rafter frame

,

galvanized steel shed frame

Frame System:
Portal Frame With Universal Column UC Verticals And Universal Beam UB Members
Column Section:
Universal Column UC Or Welded Built Up H Section, Fixed Or Pinned Base
Spanning Members:
Universal Beam UB For Beams, Tie Beams, Gable And Crane Members
Rafter Type:
Web Truss Rafter With UB Or UC Chords And Welded Web Members
Connections:
Shop Welded Plates, Site Bolted Knee Apex And Splice Connections
Bracing:
Roof And Wall Plane Bracing Set By Wind Region
Surface Treatment:
Hot Dip Galvanized After Fabrication
Galvanizing Standard:
As Named In Project Specification, Coating Class Matched To Site
Secondary Framing:
Galvanized C Or Z Purlins And Girts With Bridging And Sag Rods
Openings:
Framed Openings To Your Door Window And Louver Schedule
Design Basis:
Wind Region, Roof Load, Seismic, Crane And Mezzanine Load As Applicable
Drawings:
3D Model, General Arrangement, Erection Drawings And Anchor Bolt Plan
Packing:
Bundled By Piece Mark, Loaded In Erection Sequence
Erection:
Bolted Site Assembly With Piece Marked Members
Frame System:
Portal Frame With Universal Column UC Verticals And Universal Beam UB Members
Column Section:
Universal Column UC Or Welded Built Up H Section, Fixed Or Pinned Base
Spanning Members:
Universal Beam UB For Beams, Tie Beams, Gable And Crane Members
Rafter Type:
Web Truss Rafter With UB Or UC Chords And Welded Web Members
Connections:
Shop Welded Plates, Site Bolted Knee Apex And Splice Connections
Bracing:
Roof And Wall Plane Bracing Set By Wind Region
Surface Treatment:
Hot Dip Galvanized After Fabrication
Galvanizing Standard:
As Named In Project Specification, Coating Class Matched To Site
Secondary Framing:
Galvanized C Or Z Purlins And Girts With Bridging And Sag Rods
Openings:
Framed Openings To Your Door Window And Louver Schedule
Design Basis:
Wind Region, Roof Load, Seismic, Crane And Mezzanine Load As Applicable
Drawings:
3D Model, General Arrangement, Erection Drawings And Anchor Bolt Plan
Packing:
Bundled By Piece Mark, Loaded In Erection Sequence
Erection:
Bolted Site Assembly With Piece Marked Members
Universal Column UC Universal Beam UB Frame Industrial Steel Buildings Web Truss Rafter Galvanized Shed
Industrial Steel Buildings

Universal Column UC and Universal Beam UB Frame for a Galvanized Steel Shed with Web Truss Rafters

One frame package, engineered as a system: UC columns carrying the load down, UB members and web truss rafters carrying it across, every connection detailed in the shop, and the whole frame galvanized after fabrication.

UC ColumnsUB FrameWeb Truss RaftersGalvanized ShedFrame PackageBuilt To Your Drawing

This product is the structural frame itself, not a finished catalogue building. It is quoted as a frame package: columns, beams, truss rafters, bracing, connections, anchor details and the drawings that hold them together. The shed around it is configured to suit the frame, so the frame is detailed first and the envelope follows.

Universal Column UC Universal Beam UB Frame Industrial Steel Buildings Web Truss Rafter Galvanized Shed

How The Frame Carries Load

RoofSheeting and purlins deliver roof load to the top chord of each rafter.
RaftersWeb truss rafters span between frames and deliver the load to the column tops.
ColumnsUC columns carry the vertical load to the base plates and the foundation.
BracingRoof and wall bracing take the horizontal loads to the ground.
FrameKnee and apex connections tie rafter and column into a moment frame.
BaseAnchor bolts resist uplift and shear at each column position.

Every element in that path is a design variable, not a catalogue item. Change the span and the truss depth changes. Change the wind region and the bracing layout changes. Change the crane and the column section changes.

UC Columns And The UB Frame

Universal Column UC For The VerticalUC sections suit compression members, with the depth and mass selected for the load and the height. Base plates, cap plates and stiffeners are welded and drilled before galvanizing.
Universal Beam UB For The SpanUB sections suit bending members: roof beams, tie beams, crane beams, lintels and gable members, chosen for the moment and deflection limits the design requires.
Mixed With Web Truss RaftersWhere a solid rafter would be too deep or too heavy, the rafter becomes a truss with UB or UC chords and welded web members.
Welded Built Up Where NeededNon standard depth, wider flange or heavier section is built up from plate, so the frame is not limited by the rolled range.

Frames are detailed bay by bay. A repeat bay uses the same member set, while a wider span, a door opening, a crane bay or a mezzanine bay gets its own frame detail. The piece marks follow that logic, so erection matches the drawing sequence.

Universal Column UC Universal Beam UB Frame Industrial Steel Buildings Web Truss Rafter Galvanized Shed

Connections And Bracing

  • Knee and apex connections, bolted with shop drilled plates and site fitted bolts
  • Column base details with base plate, stiffeners, holding down bolts and grout allowance
  • Rafter splices positioned for transport length and site access
  • Purlin cleats, sag rod positions and fly bracing points welded in the shop
  • Roof plane and wall plane bracing designed for the wind case at your site
  • Gable wind columns and their connections where the end wall needs support
  • Every plate and hole detailed on the erection drawing, nothing to mark out on site

Galvanizing The Frame

The frame is hot dip galvanized after it is fully fabricated, so the coating reaches the cut ends, the inside of every bolt hole and the weld toes. Members that are closed are vented and drained as part of the detail, and threads are protected or re tapped after dipping.

  • No site painting for the frame, and no recoating cycle above working height
  • Coating mass and thickness checked per batch, with a report issued
  • Galvanizing to the standard named in your specification, coating class matched to the site environment
  • Duplex system available where a finished colour is required over the zinc

Custom Frame Options

Because the frame is detailed rather than selected, the list below is open. Each item is set by your drawing, your load case or your specification.

Geometry

  • Clear span, single span or multi span, and the number of frames
  • Bay spacing and the number of bays, including unequal end bays
  • Eave height, ridge height and roof pitch, gable or monoslope
  • Clear height under the haunch and usable height at the eaves

Frame Members

  • Column section and orientation, UB or UC, fixed or pinned base
  • Rafter type: web truss with chord and web member arrangement, or solid UB rafter
  • Haunch length and depth, knee and apex plate arrangement
  • Tie beams, ridge members and gable frame members
  • Crane runway beams, brackets and crane column detail

Secondary And Envelope Interface

  • Purlin and girt layout, galvanized C or Z, with bridging and sag rods
  • Cladding interface: single skin, sandwich panel, or a mixed roof and wall system
  • Opening frames for roller doors, access doors, windows and louvers
  • Gutter brackets, downpipe positions, canopy and awning framing

Design Basis

  • Wind region, terrain category and cyclonic exposure where applicable
  • Roof live load, collateral load and hanging services load
  • Seismic parameters and importance level
  • Crane capacity, hook height and duty class
  • Mezzanine framing and floor load where a floor is included

Shop And Documents

  • 3D model, general arrangement drawings and erection drawings
  • Piece marks stencilled on each member and matched to the packing list
  • Mill test certificates per heat number and coating inspection report
  • Anchor bolt setting plan issued early so the foundation can be poured on time
  • Loading plan packed in erection sequence for container or break bulk
If you have a drawing, we detail from it. If you do not, send the span, length, eave height, roof pitch, wind region and what the shed will be used for, and we will size the frame and quote it.

Frame Package Contents

  • UC columns with base plates, stiffeners and cleats
  • UB beams, tie beams and gable members
  • Web truss rafters with bolted site splices
  • Roof and wall bracing, sag rods and fly braces
  • Purlin and girt system
  • Structural bolts, anchor bolts and fixing accessories
  • General arrangement, erection drawings and packing list

From Drawing To Delivered Frame

  • You send the shed dimensions, the wind region and the intended use, or an existing drawing set.
  • We size the UC columns and UB members, set the truss rafter depth and issue a quotation.
  • General arrangement drawings are issued for your approval, followed by erection drawings.
  • Members are cut, drilled, welded, trial assembled where required and piece marked.
  • The complete frame is hot dip galvanized, inspected and issued with a coating report.
  • Members are bundled by piece mark and loaded in the sequence the site will erect them.
Send your span and eave height for a frame quotation Drawings or just dimensions, both are enough for us to detail the frame and price it.