logo
FAMOUS Steel Engineering Company
products
products
Home > products > Industrial Steel Buildings > Multi Span Industrial Steel Buildings Web Truss Rafters Galvanized UB UC Columns Steel Warehouse

Multi Span Industrial Steel Buildings Web Truss Rafters Galvanized UB UC Columns Steel Warehouse

Product Details

Place of Origin: Zhejiang, China

Brand Name: FAMOUS

Certification: ISO 9001

Model Number: Multi Span Truss Rafter Warehouse

Payment & Shipping Terms

Minimum Order Quantity: 1000

Price: USD 12-20/SQM

Packaging Details: Steel strapped bundles with edge protection, marked with profile, thickness and length, loaded in 20ft or 40ft container

Delivery Time: 15 to 25 days after drawing confirmation

Payment Terms: L/C,D/A,D/P,T/T

Supply Ability: 2,000 – 5,000 MT/month

Get Best Price
Highlight:

multi span steel warehouse

,

multi span truss rafter

,

galvanized UC column frame

Span Layout:
Number Of Spans Equal Or Unequal Set By Floor Plan
Internal Columns:
UB Or UC Internal Column Lines Shared Between Two Rafters
Rafter Type:
Web Truss Rafter Per Span With UB Or UC Chords
Truss Depth:
Set Per Span By Span Width Roof Load And Deflection
Valley Drainage:
Valley Gutter Size Fall Outlets And Downpipe Routing Detailed
Surface Treatment:
Hot Dip Galvanized After Fabrication
Galvanizing Standard:
As Named In Project Specification With Coating Class Matched To Site
Secondary Framing:
Galvanized C Or Z Purlins And Girts With Bracing And Sag Rods
Cladding:
Single Skin Sheeting Or Insulated Sandwich Panel As Specified
Openings:
Framed Openings To Door Window And Louver Schedule
Extension:
Bay Module Repeatable For Future Length Or Width Extension
Design Basis:
Wind Region Roof Load Deflection Limit Seismic And Crane Load As Applicable
Documents:
3D Model GA And Erection Drawings Anchor Plan And Packing List
Erection:
Bolted Site Assembly With Bay Referenced Piece Marks
Span Layout:
Number Of Spans Equal Or Unequal Set By Floor Plan
Internal Columns:
UB Or UC Internal Column Lines Shared Between Two Rafters
Rafter Type:
Web Truss Rafter Per Span With UB Or UC Chords
Truss Depth:
Set Per Span By Span Width Roof Load And Deflection
Valley Drainage:
Valley Gutter Size Fall Outlets And Downpipe Routing Detailed
Surface Treatment:
Hot Dip Galvanized After Fabrication
Galvanizing Standard:
As Named In Project Specification With Coating Class Matched To Site
Secondary Framing:
Galvanized C Or Z Purlins And Girts With Bracing And Sag Rods
Cladding:
Single Skin Sheeting Or Insulated Sandwich Panel As Specified
Openings:
Framed Openings To Door Window And Louver Schedule
Extension:
Bay Module Repeatable For Future Length Or Width Extension
Design Basis:
Wind Region Roof Load Deflection Limit Seismic And Crane Load As Applicable
Documents:
3D Model GA And Erection Drawings Anchor Plan And Packing List
Erection:
Bolted Site Assembly With Bay Referenced Piece Marks
Multi Span Industrial Steel Buildings Web Truss Rafters Galvanized UB UC Columns Steel Warehouse
Industrial Steel Buildings

Multi Span Steel Warehouses with Web Truss Rafters and Galvanized UB UC Columns

When the floor area is large but the clear span does not have to be, a multi span frame is the economical answer: internal column lines divide the roof into shorter spans, each carried by its own web truss rafter, and the whole frame is galvanized after fabrication.

Multi SpanInternal Column LinesWeb Truss RaftersGalvanized UB UC ColumnsValley DrainageSteel Warehouse
Multi Span Industrial Steel Buildings Web Truss Rafters Galvanized UB UC Columns Steel Warehouse

How A Multi Span Frame Works

In a multi span warehouse the roof is divided into spans by internal column lines. Each span has its own truss rafter running from one column line to the next, and the internal columns take load from two rafters meeting at the same line. The result is a shorter, lighter rafter for each bay, at the cost of a column grid on the floor.

That trade is usually worth it. A larger floor area covered by several moderate spans normally uses less steel than the same area covered by one very wide clear span, and it is far easier to extend later, because the structure already has a repeatable module.

Span Configurations

Configuration Internal Column Lines Typical Use Watch Out For
Single span None Machinery sheds, courts, storage where the floor must stay clear Longest rafters and heaviest columns, so the highest steel content per square metre
Two spans One central line Warehouses where one row of columns can sit along the natural aisle divider Central valley gutter has to be drained from inside the building
Three or more equal spans Two or more lines Large distribution floors, production halls, bonded warehouses Repetition is the economy, so the bay module has to suit the racking layout
Unequal spans Mixed Buildings where one wide bay is needed beside narrower storage bays Each span is designed on its own, so member sizes differ across the frame
Clear span plus multi span Partial One wide operating bay with column supported storage bays beside it Frame line between the two systems needs a proper transfer detail

Table 1: the layouts we quote most often, and the detail that decides each one.

Internal Columns And Valley Beams

Shared Column LinesAn internal column carries the reaction from the rafter on each side, so the section is chosen for combined load and for the two knee connections landing on it.
Valley BeamsWhere two roof planes meet over an internal line, the valley carries roof water along the building before it reaches a downpipe.
Column OrientationInternal columns are oriented so the knee plates of both rafters fit without welding on site, and so the flanges take the bolt groups cleanly.
Bracing LayoutWith more column lines, the bracing can be distributed between lines, which keeps individual brace forces and member sizes down.

Drainage Is The Detail That Sinks Multi Span Buildings

Every internal valley is a place where water has to be collected and taken out, and unlike an eave gutter it cannot simply discharge at the wall. This is where multi span projects often go wrong, so it is detailed at design stage rather than left to the site.

  • Valley gutter sized for the roof area draining into it, not for the width of one bay
  • Downpipe positions set inside the building or in a protected recess, agreed before the slab is poured
  • Gutter fall and expansion allowance shown on the drawing, with the outlet detail fixed
  • Sump and overflow arrangement so a blocked outlet does not back water into the roof
  • Gutter brackets and penetration flashings detailed with the cladding package
  • Access for cleaning and inspection considered while the frame is still on paper

Truss Rafters Across Different Spans

Each span gets its own rafter detail. An equal span module repeats the same truss, which keeps the jigs, the piece marks and the packing simple. When spans are unequal, the truss depth and chord section change from bay to bay, and that has to be visible on the erection drawing so the right truss goes to the right bay.

  • Truss depth and chord section set per span, with the web member pattern following the panel points
  • Purlin lines carried across spans so the roof plane stays continuous over valleys
  • Bracing and fly braces located where the roof plane changes direction
  • Splices and lifting points set for the actual truss length in each bay
  • Piece marks that state the bay, so a like sized truss is not installed in the wrong span

Multi Span Industrial Steel Buildings Web Truss Rafters Galvanized UB UC Columns Steel Warehouse

Built For Later Extension

Repeatable ModuleThe frame is set out in bay modules, so a future extension repeats the same section set instead of starting a new design.
Extend The LengthAdding bays to the gable end is the simplest extension, because the existing frame detail carries straight on.
Extend The WidthAdding a span beside the existing building needs a new internal or external column line and a junction detail at the existing eave.
Phased ConstructionWhere the building is funded in stages, the frame can be detailed so stage two bolts onto stage one without reworking the first roof.

Galvanizing Across The Frame

Multi span frames have more members and more connections than a single span of the same area, so the coating discipline matters more, not less. Everything is fabricated first and dipped as finished members.

  • All welding, drilling and trial fit finished before dipping, so no bare steel is created afterwards
  • Internal column base plates and knee plates galvanized with the member, including the faces that will be bolted
  • Coating mass and thickness checked and reported per batch
  • Galvanizing to the standard named in your specification, coating class matched to the site environment
  • Duplex primer and top coat available where a finished colour is specified

What You Can Specify

Layout

  • Number of spans, span widths and whether they are equal or unequal
  • Building length, bay spacing and number of frames
  • Eave height, ridge height and roof pitch, gable or monoslope
  • Column grid position, so it lines up with racking and aisle layout

Members

  • Internal and external column sections in UB or UC, rolled or built up
  • Truss depth, chord section and web member pattern per span
  • Knee, apex and valley connection details
  • Crane runway beams and brackets where a bay also lifts loads
  • Mezzanine framing supported off the column lines

Roof And Drainage

  • Valley gutter size, fall and outlet positions
  • Downpipe routing inside or outside the building
  • Purlin and girt layout in galvanized C or Z
  • Single skin sheeting, insulated sandwich panel or mixed systems
  • Skylights, ridge or valley ventilation and louvers

Design Basis

  • Wind region, terrain category and cyclonic exposure where applicable
  • Roof live load, collateral load and hanging services load
  • Seismic parameters and importance level
  • Deflection limits for the cladding and for the drainage fall
Send the floor plan you want to work with, or the overall length and width plus the aisle layout. We will propose a span module, show where the internal column lines land, and detail the valley drainage at the same time, because those two decisions belong together.

Package And Documents

  • Web truss rafters per span with bolted site splices
  • Galvanized UB and UC columns, external and internal, with base plates and knee plates
  • Valley beams and gutter support framing
  • Roof and wall bracing, sag rods and fly braces
  • Purlin and girt system
  • Framed openings, gutter and canopy brackets
  • Structural bolts, anchor bolts and fixing accessories
  • 3D model, general arrangement drawings, erection drawings, anchor setting plan and packing list

Multi Span Industrial Steel Buildings Web Truss Rafters Galvanized UB UC Columns Steel Warehouse

From Layout To Delivered Frame

  • You send the floor plan or the overall dimensions, the eave height, the wind region and how the space will be used.
  • We propose a span module, check it against your aisle and racking layout, and quote the frame.
  • General arrangement drawings, member details, valley drainage and the anchor setting plan are issued for approval.
  • Members are cut, welded, drilled, trial assembled and piece marked with the bay reference.
  • The frame is hot dip galvanized, inspected and issued with a coating report.
  • Members are bundled by piece mark and bay, and loaded in erection sequence.
Send your floor plan and we will set the span module Length, width, eave height and aisle layout are enough for us to propose the grid and quote the frame.