logo
FAMOUS Steel Engineering Company
products
products
Home > products > Composite Floor Deck > Long Span Composite Deck Steel Floor Formwork ComFlor 210 Equivalent Wide Span Profile

Long Span Composite Deck Steel Floor Formwork ComFlor 210 Equivalent Wide Span Profile

Product Details

Place of Origin: China

Brand Name: FAMOUS

Certification: AS1397, EN 10346

Model Number: ComFlor 210 Equivalent Wide Span

Payment & Shipping Terms

Minimum Order Quantity: 500 square meters

Price: Quoted per project drawing and quantity

Packaging Details: Strapping bundles with lifting marks, moisture protection, loaded in 20 ft or 40 ft container

Delivery Time: 15 to 25 days after drawing confirmation

Payment Terms: L/C,D/A,D/P,T/T

Supply Ability: 20000 square meters per month

Get Best Price
Highlight:

long span composite deck

,

comflor 210 equivalent profile

,

wide span steel formwork

Steel Grade:
S280GD To S350GD, G500 Optional
Design Imposed Load:
From 2.5 KN Per Square Meter Upward
Application:
Long Span Office Floor, Warehouse Floor, Plant Room
Accessories:
End Closure, Side Lap Screw, Shear Stud, Edge Trim, Pour Stop
Steel Grade:
S280GD To S350GD, G500 Optional
Design Imposed Load:
From 2.5 KN Per Square Meter Upward
Application:
Long Span Office Floor, Warehouse Floor, Plant Room
Accessories:
End Closure, Side Lap Screw, Shear Stud, Edge Trim, Pour Stop
Long Span Composite Deck Steel Floor Formwork ComFlor 210 Equivalent Wide Span Profile
Long Span Composite Deck Steel Floor Formwork ComFlor 210 Equivalent Wide Span Profile Deep rib steel deck for long span composite floors, 210 mm rib, 600 mm cover width, unpropped construction Overview

This is a deep rib steel deck used as permanent formwork for long span composite concrete floors, produced as a wide span equivalent to the ComFlor 210 profile. The 210 mm rib raises the second moment of area of the sheet, which is what allows the deck to carry wet concrete over a longer distance between beams without temporary props.

For a long span floor the deck is usually the governing element during construction, not the finished slab. The sheet has to carry the concrete, the reinforcement, the construction load and its own weight while it is still a thin cold formed section. Span capacity is therefore set by construction stage bending and deflection, and that is the design check this profile is built around.

Long Span Composite Deck Steel Floor Formwork ComFlor 210 Equivalent Wide Span Profile

Span Performance
Sheet thicknessOverall slab depthTypical unpropped spanConstruction stage control
1.0 mm260 mmAbout 4.5 mDeflection limit L/180 or 20 mm
1.2 mm280 mmAbout 5.2 mDeflection limit L/180 or 20 mm
1.2 mm320 mmAbout 5.6 mBending and deflection combined
1.5 mm350 mmAbout 6.0 mBending and deflection combined

The figures above are typical construction stage values for normal weight concrete poured in one pass from one end. They are indicative only: the manufacturer load tables for the actual sheet thickness, slab depth and pour sequence govern, and the structural engineer confirms the final span at design stage.

Why Long Span Matters Commercially
  • Fewer secondary beams per floor, which cuts steel tonnage, fabrication hours and bolt packages
  • Fewer columns means more usable floor area and more flexible racking or partition layouts
  • Longer sheets reduce the number of end laps, so there is less fixing, less overlap waste and a faster lay down
  • Unpropped construction removes the prop inventory, the double handling between floors and the work at height to strike props
  • A shorter floor cycle lowers crane time and site supervision cost on multi storey work
  • Deeper clear spans suit buildings where columns would block function, such as plant rooms, retail floors and warehouse aisles

Long Span Composite Deck Steel Floor Formwork ComFlor 210 Equivalent Wide Span Profile

Deflection and Serviceability
  • Construction stage deflection is checked against L/180 or 20 mm, whichever is the lesser, so the slab does not pond water or crack at the supports
  • Ponding is checked for the wet concrete profile along the span, and the pour sequence is agreed before the first load is placed
  • Finished floor vibration is controlled by the slab depth and the beam grid, and is normally reviewed by the structural engineer for long span floors
  • Where the span exceeds the unpropped table, the same sheet is used in a propped sequence, so one profile can serve the whole building
Technical Data
ItemSpecification
Profile typeWide span deep rib steel deck, ComFlor 210 equivalent envelope
Rib height210 mm
Cover width600 mm
Base metal thickness0.9 mm to 1.5 mm
Sheet length1 m to 12 m, cut to the beam grid
Steel gradeS280GD to S350GD, G500 optional
Zinc coatingZ100 to Z275
StandardAS1397, EN 10346
Unpropped spanUp to 6 m, set by sheet thickness, slab depth and pour sequence
Slab depth260 mm to 400 mm overall, set by the structural design
Design imposed loadFrom 2.5 kN per square meter upward, depending on slab depth and beam grid
AccessoriesEnd closure, side lap screw, shear stud, edge trim, pour stop
Compatibility With ComFlor 210
ParameterComFlor 210This Profile
Rib height210 mm210 mm
Cover width600 mm600 mm
Sheet functionPermanent formwork for composite slabPermanent formwork for composite slab
Site fixingSide lap screw, end closure, shear studSide lap screw, end closure, shear stud
Load tablesPublished by the profile ownerManufacturer tables issued with the quotation

Compatibility is dimensional, so the sheet fits the same deck zone and fixing sequence as the ComFlor 210 profile. Span tables are not interchangeable, and the structural engineer confirms the slab design and load table for each project.

Typical Applications
  • Long span floors in multi storey steel frame office and commercial buildings
  • Column free warehouse and distribution floors where aisle layout must stay open
  • Plant rooms and service floors carrying heavy mechanical equipment
  • Retail and exhibition floors with long clear spans and exposed soffits
  • Mezzanine and transfer floors where beams must be kept to a minimum

Long Span Composite Deck Steel Floor Formwork ComFlor 210 Equivalent Wide Span Profile

Installation Sequence
  1. Beam grid and deck bearing lines are checked against the layout drawing before any bundle is opened
  2. Sheets are lifted in bundles and laid in the planned direction so the ribs run the short way across the beams
  3. Side laps are screwed at the specified centres and end closures are fitted at each sheet end
  4. Edge trim and pour stops are fixed, then shear studs are welded through the deck where composite action is required
  5. Reinforcement, services and temporary edge protection are installed with the deck acting as the working platform
  6. Concrete is poured in the agreed sequence, levelled and cured before the floor is loaded
Packing and Delivery
ItemDetail
BundleSheets strapped in bundles with lifting points marked
Moisture protectionBundles kept dry, ventilated and clear of the ground in transit and storage
MarkingLabel with sheet length, thickness, coating class, quantity and floor reference
Loading20 ft and 40 ft container, flat rack for long sheets
DeliveryCut to length and shipped in the installation sequence for each floor
Information Needed For A Quotation
  • Beam grid drawing with the deck bearing lines and the intended pour sequence
  • Sheet thickness, slab depth and design imposed load
  • Required zinc coating class and steel grade
  • Edge details, openings, pour stops and stair trimming
  • Delivery port and required date per floor

Send these details and we will return the deck quantity, accessory list, span tables and packing plan for the project. Custom cut lengths, alternative coating classes and matched accessories are available on request.